THBRVS-150-XYA instruments of Brinell hardness
Figure 1 load - indentation depth (loading and unloading) curve of a sample (HRC26.1)
Figure 2 the load varies with time (X axis unit: 1/40 sec; Y axis unit: kilogram)
The maximum force is: 150 kilograms
Figure 3 the value of indentation depth varies with time (X axis unit: 1/40 sec; Y axis unit: micron)
The maximum displacement is: 429 microns
user interface:
main interface
Brucell measurement interface
Vickers measurement interface
Rockwell measurement interface
Multipoint and multi sample measurement interface
Loading and unloading curve measurement interface